Eaton Rack PDU
Intelligent Rack PDUs  

Eaton Rack PDU models allow lights-out monitoring and control of IT devices including switching devices powered across multiple ePDUs. They include IEC Class 1 (1%) billing grade accuracy, an advanced hot-swap meter with LCD pixel display showing Voltage, Watts, Amps and kWh, and the ability to daisy chain 8 ePDUs to share the same network connection and IP address. 

Features

Rack PDU Model Matrix

Functionality Input Type Phase Input Connection Nominal Power Outlets RU Model

Outlet Switched 16 A 1-ph IEC C20 200-240 V 3.84kW 8xC13 1U Horizontal E-ESWH28

Outlet Switched 16 A 1-ph  IEC C20 200-240 V   3.84kW  20xC13 | 4xC19  0U Vertical E-ESWB22

Outlet Switched 16 A 1-ph  IEC-60309 200-240 V   3.84kW  20xC13 | 4xC19  0U Vertical E-ESWB04

Outlet Switched 32 A 1-ph  IEC-60309 200-240 V   7.4kW  20xC13 | 4xC19  0U Vertical E-ESWB05

Outlet Switched 16 A 3-ph  IEC-60309 346-415 11kW  21xC13 | 4xC19  0U Vertical E-ESWB20



Outlet Metered 16 A 1-ph  IEC-C20 200-240 V   3.84kW  20xC13 | 4xC19  0U Vertical E-EMOB22

Outlet Metered 32 A 1-ph IEC-60309 200-240 V   7.4kW  20xC13 | 4xC19  0U Vertical E-EMOB05

Outlet Metered 16 A 3-ph IEC-60309 346-415 11kW  21xC13 | 3xC19  0U Vertical E-EMOB20



Input Metered 16 A 1-ph IEC C20 200-240 V   3.84kW  8xC13   1U Horizontal E-EMIH28

Input Metered 32 A 1-ph  IEC60309 200-240 V   7.4kW  12xC13 | 4xC19  2U Horizontal E-EMIH06

Input Metered 16A 1-ph  IEC C20 200-240 V   3.7kW  20xC13 | 4xC19  0U Vertical E-EMIB22

Input Metered 16A 1-ph  IEC60309 200-240 V   3.7kW  20xC13 | 4xC19  0U Vertical E-EMIB04

Input Metered 32 A 1-ph  IEC60309 200-240 V   7.4kW 12xC13 | 4xC19  0U Vertical E-EMIB06

Input Metered 32 A 1-ph  IEC60309 200-240 V   7.4kW 20xC13 | 4xC19  0U Vertical E-EMIB05

Input Metered 32 A 1-ph  IEC60309 200-240 V   7.4kW 36xC13 | 6xC19  0U Vertical E-EMIB08

Input Metered 16 A 3-ph IEC60309 346-415 11kW 21xC13 | 3xC19  0U Vertical E-EMIB20

Input Metered 16 A 3-ph IEC60309 346-415 11kW 36xC13 | 6xC19  0U Vertical E-EMIB00

Input Metered 32A 3-ph IEC60309 346-415 22kW 12xC13 | 12xC19  0U Vertical E-EMIB12

Input Metered 32A 3-ph IEC60309 346-415 22kW 24xC13 | 6xC19  0U Vertical E-EMIB32

Input Metered 32 A 3-ph IEC60309 346-415 22kW 30xC13 | 12xC19  0U Vertical E-EMIB34

Input Metered 63 A 3-ph IEC60309 346-415 43.6kW 18xC13 | 12xC19  0U Vertical E-EMIB352

Specifications

PACKAGE CONTENTS:







FREQUENCY RATING:


OPERATING TEMPERATURE:


ETHERNET INTERFACE:


MASS CONFIGURATION:


COMMUNICATION:

      

SPECIAL FEATURES:















INPUT METERING:

OUTLET METERING:


OUTLET SWITCHING:


200-240V


     346-415V


CORD LENGTH:

     

COLOR:      


SNMP:  


MATERIAL:  


SERIAL INTERFACE:

Rack PDU

Mounting accessories

Network cable

Configuration cable

Splitter for daisy-chaining

Quickstart guide

Safety Instructions


50/60 Hz


0° to 60°C (32° to 140°F)


Yes


Yes


HTTP, HTTPS, SSL, Telnet, FTP, SNMP, SMTP, DNS, DHCP, LDAP, RADIUS


Remote Site Management

Turn off unused outlets to control commissioning

Phase Metering, Circuit Breaker Current Metering and Input Metering

Circuit Breaker Status Monitoring

Outlet and IT Equipment Switching/reboot /sequencing across A and B feed in Daisy-Chain

Sequence Outlets to avoid in-rush current, to ensure equipment starts in correct order

Hot-Swap Control module with advanced LCD

Optional Temperature/Humidity sensor

Built-in IEC outlet eGrip retention, retains all standard IEC plugs

Daisy-Chain up to 8 PDUs, reduce network infratsructure costs

Power chain monitoring & Real time Intelligence on your Data Center


All models


Outlet Metered and Outlet Switched models only


Outlet Switched models only


1-ph 16A and 32A models only


3-ph 16A, 32A and 63A models only


3m (IEC-60309 only)


Black


Yes


Aluminium


Yes